The following %-sequences are provided:
%c Current capacity (mAh or mWh)
+%r Current rate
%B Battery status (verbose)
+%d Temperature (in degrees Celsius)
%p Battery load percentage
-%L AC line status (verbose)"
- (let (charging-state
+%L AC line status (verbose)
+%m Remaining time (to charge or discharge) in minutes
+%h Remaining time (to charge or discharge) in hours
+%t Remaining time (to charge or discharge) in the form `h:min'"
+ (let (charging-state rate temperature hours
(charge-full 0.0)
(charge-now 0.0)
(energy-full 0.0)
(and (re-search-forward "POWER_SUPPLY_STATUS=\\(.*\\)$" nil t)
(member charging-state '("Unknown" "Full" nil))
(setq charging-state (match-string 1)))
+ (when (re-search-forward
+ "POWER_SUPPLY_\\(CURRENT\\|POWER\\)_NOW=\\([0-9]*\\)$"
+ nil t)
+ (setq rate (float (string-to-number (match-string 2)))))
+ (when (re-search-forward "POWER_SUPPLY_TEMP=\\([0-9]*\\)$" nil t)
+ (setq temperature (match-string 1)))
(let (full-string now-string)
;; Sysfs may list either charge (mAh) or energy (mWh).
;; Keep track of both, and choose which to report later.
(setq energy-full (+ energy-full
(string-to-number full-string))
energy-now (+ energy-now
- (string-to-number now-string)))))))))
+ (string-to-number now-string))))))
+ (goto-char (point-min))
+ (when (and energy-now rate (not (zerop rate))
+ (re-search-forward
+ "POWER_SUPPLY_VOLTAGE_NOW=\\([0-9]*\\)$" nil t))
+ (let ((remaining (if (string= charging-state "Discharging")
+ energy-now
+ (- energy-full energy-now))))
+ (setq hours (/ (/ (* remaining (string-to-number
+ (match-string 1)))
+ rate)
+ 10000000.0)))))))
(list (cons ?c (cond ((or (> charge-full 0) (> charge-now 0))
(number-to-string charge-now))
((or (> energy-full 0) (> energy-now 0))
(number-to-string energy-now))
(t "N/A")))
+ (cons ?r (if rate (format "%.1f" (/ rate 1000000.0)) "N/A"))
+ (cons ?m (if hours (format "%d" (* hours 60)) "N/A"))
+ (cons ?h (if hours (format "%d" hours) "N/A"))
+ (cons ?t (if hours
+ (format "%d:%02d" hours (* (- hours (floor hours)) 60))
+ "N/A"))
+ (cons ?d (or temperature "N/A"))
(cons ?B (or charging-state "N/A"))
(cons ?p (cond ((> charge-full 0)
(format "%.1f"